Structural Response Sensitivity to Rupture Parameter Variations: A High-Fidelity Analysis of a 10-Story Building on the San Ramón Fault

by jaabell - Tue, 03 Nov 2026
Tags: #Papers #Conference #Earthquake Engineering #Soil-Structure Interaction #Domain Reduction Method #San Ramón Fault #Interactive

My student Patricio Palacios B. is presenting this work this week at PBD-V 2026, the 5th International Conference on Performance-Based Design in Earthquake Geotechnical Engineering, in Puerto Varas, Chile (4–6 November 2026). Co-authored with Nicolás Mora Bowen and myself, the paper asks a question that matters a lot for near-fault design: if you only run one rupture scenario for a given magnitude, how wrong could your structural demand estimate be?

The answer, from a campaign of 72 soil-structure interaction analyses: quite wrong, close to the fault. We generated stochastic finite-fault ground motions for Mw 6.5 and Mw 6.6 scenarios on the San Ramón Fault (three stochastic realizations each), propagated them into a 10-story reinforced-concrete building through the Domain Reduction Method at three sites spanning 3.3 to 22.5 km from the fault, and ran a three-factor ANOVA at every floor to disaggregate response variance into magnitude, stochastic slip distribution, and source-to-site distance. Source-to-site distance dominates (60–95% of variance), but at the nearest station, inter-realization displacement differences exceed 100% — a single deterministic scenario just isn't enough to characterize near-fault structural demand.

Explore the model in 3D

Patricio built a full interactive explorer of the fault, the ground motions, the soil domain and the building response — it runs right in your browser, phone included.

🌋 Open the interactive explorer →

3D terrain model of the San Ramón Fault with the finite-fault rupture plane and recording sites, from the interactive explorer

The San Ramón Fault model and recording sites, one of eleven chapters in the interactive explorer.

QR code linking to the interactive SRF explorer

Scan to open on your phone — handy if you're at the conference.

Citation: Patricio Palacios B., Nicolás Mora Bowen, José A. Abell. Structural Response Sensitivity to Rupture Parameter Variations: A High-Fidelity Analysis of a 10-Story Building on the San Ramón Fault. 5th International Conference on Performance-Based Design in Earthquake Geotechnical Engineering (PBD-V), Puerto Varas, Chile, 2026. Read the paper (PDF)